| RS-485/232 Output |
115.2K baud |
| Environmental |
Humidity: 5% to 95%; Non-condensing |
| Temperature |
Operating: 32¤ to 131¤ F; Storage: 0¤ to 150¤ F |
| Power Requirements |
85-265 VAC 50/60Hz; Internally Fused at 1.5 Amps |
| Memory Retention Time |
Saves last programmed values for ten years without power |
| Movement Input |
85-265 VAC, 12mA (rms) maximum; Optical isolated to 3200 VDC/2250 VAC |
| Program Mode Key Input |
Dry Contact; Open Collector (drain) only; +5 VDC maximum — Current 0.2mA |
| Relay Contact Ratings |
All relays rated UL & CSA for ¼ HP, 125 to 250 VAC;
8A 250 VAC, 30 VDC, Shock Resistant to 10G |
| Shock & Vibration |
Tested to: MIL-STD 810E, Method 514.4, Category 10, 20-2K Hz,
2G sine, 0.04 G² Hz random, UL 491, SA 19, 10-150 Hz, 10 G sine |
| Electromagnetic Compatibility |
Tested to: IEC 801-2, Level 5 (Electrostatic discharge requirements);
IEC 801-4, Level 4 (Electrical fast transient/burst requirements);
IEC 801-5, Level 3.5 (Surge immunity requirements) |