Input Power 115VAC +/- 10%, single phase, 50/60 Hz
Operating Temperature 32-125 degrees Fahrenheit
Storage Temperature 0-180 degrees Fahrenheit
Maximum Resolution 1000 counts/turn
Standard Scan Time 200 microseconds
300 rpm @1000 counts per turn
Display 1 line x 16 characters LCD
Maximum Number of Lobes 238 lobes
Dimensions 7.00" W x 3.00" H x 5.75" D
Height does not include relay output board
PLS-801 Resolver Interface Electrical Characteristics
The resolver used with the PLS-801 should have the following characteristics:
Input Voltage 7.0 Vrms
Input Frequency 5000 Hz
Primary Winding Rotor (R1,R2)
Input Rotor Current (max) 10.9 mA
Input Power 47 mW
Output Voltage (stator windings) 6.7 Vrms
Transfer Ratio .95
Phase Shift (open circuit) Leading -6 Degrees
Sensitivity 116 mV/deg.
DC Rotor Resistance 16 ohms +/- 10% ohms
DC Stator Resistance 52 ohms +/- 10% ohms
Total Null Voltage 15 mV
Accuracy Maximum Error +/-7 Minutes