| Input Power |
115VAC +/- 10%, single phase, 50/60 Hz |
| Operating Temperature |
32-125 degrees Fahrenheit |
| Storage Temperature |
0-180 degrees Fahrenheit |
| Maximum Resolution |
1000 counts/turn |
| Standard Scan Time |
200 microseconds 300 rpm @1000 counts per turn |
| Display |
1 line x 16 characters LCD |
| Maximum Number of Lobes |
3808 238 lobes x program x group = 238 x 4 x 4 |
| Dimensions |
7.00" W x 4.75" H x 5.75" D |
|
 |
| PLS-601 Resolver Interface Electrical Characteristics |
| The resolver used with the PLS-601 should have the following characteristics: |
| Input Voltage |
7.0 Vrms |
| Input Frequency |
5000 Hz |
| Primary Winding |
Rotor (R1,R2) |
| Input Rotor Current (max) |
10.9 mA |
| Input Power |
47 mW |
| Output Voltage (stator windings) |
6.7 Vrms |
| Transfer Ratio |
.95 |
| Phase Shift (open circuit) Leading |
-6 Degrees |
| Sensitivity |
116 mV/deg. |
| DC Rotor Resistance |
16 ohms +/- 10% ohms |
| DC Stator Resistance |
52 ohms +/- 10% ohms |
| Total Null Voltage |
15 mV |
| Accuracy Maximum Error |
+/-7 Minutes |
|
|