| No. of Channels |
One or Two |
| Sensor Inputs |
Full bridge strain gage sensors
120 to 1000 ohms Up to (2) 350 ohm sensors |
| Sensor Excitation |
Built-in 10VDC @ 475mA max
(Short circuit protected) |
| Automatic Zero Balance |
Yes |
| Balance Range |
+/- 1mV/V of offset |
| Gain Range |
Low Gain = 0.568mV/V to 5.000mV/V
High Gain = 0.057mV/V to 0.625mV/V |
| Analog Output |
.025" header 2.5VDC @ Press Capacity |
| Accuracy |
+/- 1% of full scale max |
| Non-linearity |
+/- .1% of full scale max |
| Frequency Response |
Flat DC to 1KHz |
| Display |
4 digit display |
| Display Update |
2 updates per second |
| Resolution |
1024 count |
| Strokes per Minute |
300 SPM (threshold trigger) 800 SPM (probe trigger) |
| Calibration Shunts |
1 Meg Ohm .1% precision resistor |
| Computer Interface |
(2)RS-485 |
| Trigger |
Probe or Threshold |
| Threshold Probe |
Accept 24-115V AC or DC (Built-in voltage source of 115VAC).
It supports limit switch, solid state or mechanical relays |
| Resolver Interface |
No |
| Shutdown Relay |
10A @ 120VAC N.O. Contact Bypass switch available |
| Power Requirements |
69 Watts max, 95-130VAC @ 50-60Hz
or 190-260VAC @ 50-60Hz |
| Operating Temperature |
0-70 degrees Celsius |
| Dimensions |
12.5" W x 14.5" H x 6.8" D |
| Weight |
Approximately 25.8lbs |