Tonnage Monitors - View All
All-In-One Systems - View All
Load Cells - View All
Press Controls - View All
Software - View All
Die Protection - View All
PLS - View All
Press Calibration - View All
Miscellaneous - View All
Die Protection  
Inputs 16
Sensor Type Momentary (1 to 50 max cycle), maintained (1 to 50 max cycle),
static NO, static NC
Built-in Power For Sensors 24VDC, 750mA max
Tonnage Monitoring  
Channels 2 or 4
Sensor Inputs Full bridge strain gages, 120 to 1,000 ohms, up to (8) 350 ohm sensor inputs
Sensor Excitation Built-in 10VDC @ 500mA max. (short circuit protected)
Automatic Zero Balance Yes
Balance Range +/- 1mV/V of offset
Gain Range 100 to 11,000x (digitally controlled)
Analog Output 1.25VDC at press capacity
Analog Output Connection .15"pitch Phoenix connector
Inaccuracy +/-1% of full scale max
Non-Linearity +/-.1% of full scale max
Frequency Response Flat DC to 6KHz
Resolution Each channel provides a 4-digit load value in 1024 count
Calibration Shunts Calculation based on 1 Meg Ohm shunt resistor
PLS  
Outputs 8
Position Output Up to 2 on/off windows
Timed Output 1 to 10 seconds
Speed Compensation Individual speed compensation value for each output
Turn on at Cycles Every 1 to 250 cycles
Mechanical Relay NO and NC contacts, 10 AMP @ 250VAC, 10 AMP @ 30VDC
Solid State Relay (optional) NO contact, 3 AMP @ 140VAC
Motion Detect  
Start Time Limit Adjustable up to 800ms
SPM Limit Max and min limits, SPM motion output relay (same as PLS)
Drift Detection Alarm when 3 or more degrees of incorrect motion is detected
Dual Safety Valve Input 110VAC mechanical relay (other voltage available)
Shutdown Relays  
Top Stop & E-Stop Same type as PLS
HMI  
Display Bright 6.5" diagonal TFT LCD
Keypad Menu driven, alpha-numeric
General  
Resolver Built-in excitation supports standard 5000Hz rotor excited positional resolver
Computer Interface (3) RS-485/232 serial ports
Flash Disk 8 MB Compact Flash
Power Requirements 95 Watts max, 85-132VAC @ 50-60Hz OR 170-264VAC @ 50-60Hz
Operating Temperature 0-50 degrees Celsius
Dimensions 12.5"x14.5"x6.78"D