Pressnet tonnage monitoring software

PressNet networking software provides detailed production and tonnage information at your fingertips. The current die/part number, working tonnage, production count, high and low tonnage setpoints, etc. can be viewed easily by networking tonnage monitors. PressNet also includes PN Reporter. It easily accumulates reports such as: press downtime, job run time and parts produced during each production run.

PressNet provides information for each press, such as:
  • Part, press & die number
  • Downtime & reasons (N260 only)
  • Current working tonnage
  • Highest & lowest tonnage
  • High & low tonnage alarm limits
  • Press capacity
  • Batch counter (N260 only)
  • Part counter
  • Number of alarms
  • Last alarm
  • Last high & low tonnage alarms
  • Generates SPC load files
PressNet
PressNet Pressroom Screen:
This is the main pressroom page. Each box represents a press with a production monitor that is on the network. Current production count or total tonnage is displayed and a color coded bar indicates the press status. A green box indicates a press
running within the high and low tonnage limits. Red signifies an alarm condition. A yellow box indicates a press is idle. When the press status is outlined in blue, the tonnage monitor is in setup mode.
PressNetHard Hit Report:
PressNet automatically generates a daily Hard Hit Report. Every over capacity (Cap), Critical Curve Monitoring (CCM)(N260 only) and high setpoint (High) violation is accumulated and displayed in this report. It also lists the press number, part number, date and time of the alarm violation. The associated tonnage signature is automatically saved (with TT Graph) and can be easily viewed by simply double-clicking on the alarm. This makes reviewing over tonnage conditions convenient and easy. This report is an option.
Options:
  • Hard hit report
  • Hard hit alarm signature report
  • TT SPC software
  • "Cookbook" tonnage
  • Auto data purge
  • Auto die set
  • PMIS interface
  • Tonnage file format
  • Part number file format